Burner controls

Siemens LME burner controls (LME11 / LME21 / LME22 / LME41 / LME44 / LME7)

Microprocessor burner controls for forced-draught gas burners in intermittent operation; LME1 / LME2 for one- and two-stage burners, LME4 for larger burners, LME7 programmable with display; ionization or QRA / QRB / QRC detection depending on type.

WhatsApp an engineer Replacement quote

How we help

For a burner control or relay module, send the full part number from the label (for example RM7840L1018), the supply voltage and the flame detector used. Controls must match the original sequence and safety timings, so we always check these before quoting.

Where it is used

LME controls run the start-up sequence and flame supervision on forced-draught gas burners in intermittent operation: the monoblock burners found on boilers, hot-water heaters, ovens, dryers and small process heaters. They replaced the older LGB and LMG controls on many European burners.

Why it gets replaced

Plants call us when a burner keeps locking out and the control is suspected, when a unit is damaged by moisture or a voltage spike, or when an old LGB / LMG has failed and the LME that replaced it has to be matched to the same burner. The coloured signal lamp on the LME gives a blink code that tells us whether the control or the burner is the real problem.

Send us before we quote

  • Full type code from the label, for example LME22.331C2 (the digits after the point set the timings, the suffix the supply voltage)
  • Burner make and model
  • Flame detection used: ionization electrode, QRA UV or QRB photocell
  • One-stage, two-stage or modulating burner
  • Blink code shown before the unit failed, if you noted it

Often replaced together with

  • Ionization electrode or QRA / QRB flame detector
  • Ignition transformer and electrode
  • Gas solenoid valves and air pressure switch
  • Plug-in base / connector set

If the original is still made, we get it for you. If it is not, we offer a part that fits the same mounting and wiring, and tell you what is different before you order.

Model numbers we are often asked about

LME11.330C2, LME21.130C1, LME21.130C2, LME21.231C2, LME21.330C1, LME21.330C2, LME21.350C1, LME21.350C2, LME21.430C2BT, LME22.232C2, LME22.233C2, LME22.331C2, LME41.054C2, LME44.056C2, LME71, LME73. Not on the list? Send the full model string from the nameplate.

Replacing an LGB or LMG? Common pairs: LGB21.130A27 / LMG21.130B27 → LME21.130C2, LGB21.330A27 / LMG21.330B27 → LME21.330C2, LGB21.130A17 → LME21.130C1 (120 V). The C1 / C2 suffix is 120 V / 230 V. Check the timings of your burner before ordering.

Red lamp on? See Siemens LME blink codes explained.

Brand and model names are used only to identify the equipment. They are trademarks of their respective owners; SENNISI is an independent company and is not affiliated with these manufacturers.

Related models

Send us your nameplate.

A nameplate photo, or your heat load, fuel and gas pressure. The reply comes from an engineer.