Manuals

Manuals & datasheets.

Where to find the official manuals, catalogs and datasheets for Maxon and Eclipse industrial burners, Honeywell and Kromschröder burner controls, flame detectors, gas valves, pressure switches and modulating actuators — the equipment we most often service and replace. Each link opens the manufacturer's own product page, where the PDFs are free to download. Looking for a replacement or spare parts? See our replacement burners or send us your nameplate.

Maxon

OVENPAK 400Nozzle-mixing gas burner for ovens, dryers and air heatersTechnical catalog · Bulletin 2100 · spare partsReplacement quoteWhatsAppOfficial PDFs ↗
OVENPAK LELow-emission version of the OVENPAK for direct and indirect firingTechnical catalog · brochureReplacement quoteWhatsAppOfficial PDFs ↗
VALUPAK / VALUPAK-IIPackaged gas burner for process air heating (VALUPAK replaced by VALUPAK-II)Bulletins · spare partsReplacement quoteWhatsAppOfficial PDFs ↗
KINEMAXMedium-velocity burner for furnace circulation and uniformityTechnical catalog · operating instructionsReplacement quoteWhatsAppOfficial PDFs ↗

Eclipse

RatioMatic RM0100 / RM0200 / RM0300 / RM0400 (RM0050 – RM3000)Packaged nozzle-mix air-heating burner for ovens, dryers and direct / indirect air heatersDesign guide · datasheets per size · installation guideReplacement quoteWhatsAppOfficial PDFs ↗
ThermJet TJ0015 – TJ2000High-velocity nozzle-mix burner for furnaces and kilnsDesign guide · datasheets per size · installation guideReplacement quoteWhatsAppOfficial PDFs ↗
AirHeat AH-MALine burner for make-up air and process air heatingOperating instructions · brochure · datasheetsReplacement quoteWhatsAppOfficial PDFs ↗
Incini-ConeDuct burner for fume incineration and exhaust after-heatingDatasheet · spare partsReplacement quoteWhatsAppOfficial PDFs ↗
RHT indirect air heaterIndirect air heating where combustion products must stay out of the process airDimensions · datasheetsReplacement quoteWhatsAppOfficial PDFs ↗

Burner controls

Honeywell 7800 SERIES burner controlsRM7800 / EC7800 / RM7840 / RM7890 relay modules, flame amplifiers, display moduleProduct data · installation instructions · wiringReplacement quoteWhatsAppOfficial PDFs ↗
Kromschröder BCU 370Burner control for modulating forced-draught gas burners, with fan and butterfly valve controlTechnical information · operating instructionsReplacement quoteWhatsAppOfficial PDFs ↗
Kromschröder BCU 560 / 565 / 580Burner control units for single and forced-draught burners in furnacesTechnical information · operating instructionsReplacement quoteWhatsAppOfficial PDFs ↗
Kromschröder BCU 4 series (BCU 460 / 465 / 480)Next-generation modular burner control for multi-burner furnacesBrochure · technical informationReplacement quoteWhatsAppOfficial PDFs ↗
Kromschröder IFD 258 / IFD 244Automatic burner control units for directly ignited gas burners in continuous operation, with flame-signal displayTechnical information · operating instructionsReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell TBC2800 digital burner controllerBurner controller for gas burners in pulse-firing and modulating systems, multi-burner furnaces and kilnsProduct handbook (EN / 中文) — ask usReplacement quoteWhatsApp
Honeywell R4343 flame switch (R4343D / R4343E)Flame relay for intermittent industrial burners; spare-part only, being replacedProduct data · replacement informationReplacement quoteWhatsAppOfficial PDFs ↗

Flame detectors

Honeywell C7027 / C7035 Minipeeper UV detectorsUV flame sensors used with 7800, TBC2800 and other Honeywell burner controlsProduct data · spare UV tubesReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell C7061 self-check UV detectorDynamic self-check UV sensor for continuous-operation burnersProduct data · installation instructionsReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell C7012 Purple PeeperSolid-state UV flame detector for industrial burnersProduct dataReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell R7849 / R7861 / R7847 flame amplifiersPlug-in UV and rectification amplifiers for 7800 SERIES relay modulesProduct data · amplifier / detector pairing tableReplacement quoteWhatsAppOfficial PDFs ↗

Gas valves, pressure switches & temperature controllers

Honeywell VE4000 / VE5000 gas solenoid valvesClass A normally-closed gas shut-off valves, DN10 – DN100, for burner gas trainsInstruction sheet · technical dataReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell C6097 gas / air pressure switchesLow / high gas and air pressure switches for burner gas trainsProduct data · technical informationReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell L404F PressureTrolPressure controllers for steam, gas and oil lines up to 300 psiProduct dataReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell DC1040 temperature controller (DC1000 series)PID temperature controllers for furnaces, ovens and dryers (DC1010 / 1020 / 1030 / 1040)Product manual · specificationReplacement quoteWhatsAppOfficial PDFs ↗

Actuators / modulating motors

Kromschröder IC 20 / IC 30 / IC 40 / IC 500–90° actuators for gas and air butterfly valves (3-point, 4–20 mA, programmable)Technical information · operating instructionsReplacement quoteWhatsAppOfficial PDFs ↗
Honeywell Modutrol IV (M7284 / M7285 / M7294)Modulating motors for burner air dampers and gas valves (4–20 mA)Product data · specification dataReplacement quoteWhatsAppOfficial PDFs ↗

Maxon, Eclipse and Kromschröder are brands of Honeywell; all documents are published and hosted by the manufacturer. Honeywell, Modutrol, Maxon, OVENPAK, KINEMAX, VALUPAK, Eclipse, AirHeat, ThermJet, Incini-Cone, Exothermics, Kromschröder, BCU, Minipeeper, Purple Peeper and PressureTrol are trademarks of their respective owners. SENNISI is an independent company and is not affiliated with these manufacturers.

Send us your nameplate.

A nameplate photo, or your heat load, fuel and gas pressure. The reply comes from an engineer.

WhatsApp an engineer →   [email protected]